Industrial Projects

 

Power Generation

Pioneer Generation Station
PacifiCorp
Ogden, Utah

Coldsweep, Inc. cleaned two badly contaminated hydroelectric generators at this site using our dry ice dusting process. Specialized equipment shaves sugar-sized particles of dry ice from blocks of dry ice then propels it at low pressure to gently clean delicate components.

 

Dry Ice Blasting PacifiCorp Hydro-Electric Generator Rotor

     

The cooling slots in the adjacent stator were plugged with a combination of lubricant fron an oil leak and cottonwood seed cotton. Dry ice blasting removed the contaminants with dramatic results. The cleaned generator ran much cooler after the cleaning was complete.

The risk of fire from overheating was substantially reduced so the generator RPM's could be increased.

  Dry Ice Blasting PacifiCorp Hydro-Electric Generator Stator
     

A modular containment system was errected to ensure that adjacent work areas were not contaminated during the cleaning process. This containment also utilized a 2500 CFM, HEPA-Rated air scrubber to create a negative air space while the dry ice blasting was performed.

If you have similar issues at your facility, please give us a call to discuss the benefits of dry ice blasting.

  Portable Containment Erected to Create Negative Air Space
     

Flathead Lake Hydroelectric Generator

GE Power Systems / Montana PPL
Polson, Montana

The stator and rotor for this 28-foot diameter generator was gently cleaned using block shaving dry ice blasters to clean damaged insulation during a major overhaul.

 
     

Rifle Generating Station
Tri-States G&T
Rifle, Colorado


Coldsweep performed high-pressure dry ice blasting to remove combustion products from turbine components. During a subsequent shutdown rust was removed from components that corroded during storage.

 
     

Bear Lake Pump Station
PacifiCorp
Lifton, Idaho


Coldsweep, Inc. cleaned the stator and rotors windings for several 14-foot diameter pump motors. The fragile insulation on the motor windings was badly contaminated. Our non-abrasive cleaning method (dry ice dusting) gently cleaned the 100-year old insulation during a major overhaul of the motors.

 
     

U.S. Borax Co-Generation Plant
Rio Tinto
Boron, California


Fouled economizer fins were dry ice blasted to remove contaminants that were causing excessive backpressure. Technicians safely removed combustion deposits from Teflon-coated diaphragms and cleaned the turbine rotor in place.